Live Training

Call for Price.

A half or full day of training on the uses of microfat and MiniTC. The class will include discussion and live cases. All three dimensions of a microfat procedure will be addressed – the liopaspiration, MiniTC microfat processing, and re-injection.

Prior sessions have been well attended and very successful, generating accolades from the doctors who have attended.

To order call: 800-217-0491

Fat vs Microfat Infographic

20″ x 34″ poster on quality paper stock, suitable for examination rooms or waiting rooms.

Displays simple definitions of fat and microfat, and the importance of and uses for both.

If you prefer to print yourself, you can download this infographic for free at jointechlabs.com/your-fat-cell-infographic/

To order call: 800-217-0491

Patient Brochure

Tri-fold consumer brochure answering “why microfat?” Includes a discussion of the patient benefits of a microfat procedure with MiniTC.

Price is for 100 brochures. Stand sold separately.

To order call: 800-217-0491

Mini-X Device Stand

3D printed, Blue Resist Color, for holding MiniTC and Mini-Stem devices during processing, designed to fit the protocol for MiniTC and Mini-Stem. Non-sterile, reusable.

Use sterile cover for use in sterile fields.

To order call: 800-217-0491

Decanting Rack

Rack for decanting of capped syringes in non-sterile field, compatible with BD syringes 50/60 ml. Capacity: 4 syringes. Plastic, non-sterile, reusable. Not suitable for sterile fields. 

To order call: 800-217-0491

Counter Balance Unit

Non-sterile replacement unit for counterbalance on the BiospinX centrifuge.

Reusable, do not discard! 

To order call: 800-217-0491

Harvester Cannula

Disposable, stainless steel, 16 holes, both ends bevelled, blunt end, Luer-Lok

Dimensions: 18.5 cm, 2.5 mm OD

To order call: 800-217-0491

Infiltration Cannula

Disposable, stainless steel, spiral port, 6 holes (large fenestrations, blunt end, Luer-Lok)

Dimensions: 18.5 cm, 2.5 mm OD

To order call: 800-217-0491

FatLok Syringe

Adipose aspiration syringe uniquely designed to generate negative pressure for safe fat aspiration. Self locking, no need for additional accessories to hold the negative pressure. Planger offers smooth movements preventing accidental spills. Sterile, Luer-Lok, single use (can be conveniently reloaded during the same procedure).

Note: Cannulas and Decanting Rack are not included, they are available separately.

To order call: 800-217-0491

BiospinX Centrifuge

Proprietary benchtop centrifuge. Designed and preset for MiniTC and Mini-Stem System devices.

Note: adaptor inserts for multiple PRP systems are in development and will be offered at no additional cost.

Warranty: 2 years

To order call: 800-217-0491

Disposable Capacity2 disposables (Up to diameter of 91.4 mm / 3.60 in) (Up to length of 137.2mm / 5.40 in)
Dimensions (H x W x D)15 in x 18 in x 10 in (38 cm x 46 cm x 25 cm)
Weight37 lbs. (18 kg)
Sound Level67 dB A
Environmental Range16 – 32° C
Voltage95 -253 VAC
Frequency50/60 Hz
Power Requirement350 Watts
Centrifuge Motor½ H.P. Brushless
Max Speed3,200 RPM (+/- 100)
Max G-Force1,800 xg
Max Carrier Load350.0 grams
Max Imbalance5.0 grams
Cycle Time.5 to 99 minutes (+/- 2%)